511 research outputs found

    Three-Dimensional Spectral-Domain Optical Coherence Tomography Data Analysis for Glaucoma Detection

    Get PDF
    Purpose: To develop a new three-dimensional (3D) spectral-domain optical coherence tomography (SD-OCT) data analysis method using a machine learning technique based on variable-size super pixel segmentation that efficiently utilizes full 3D dataset to improve the discrimination between early glaucomatous and healthy eyes. Methods: 192 eyes of 96 subjects (44 healthy, 59 glaucoma suspect and 89 glaucomatous eyes) were scanned with SD-OCT. Each SD-OCT cube dataset was first converted into 2D feature map based on retinal nerve fiber layer (RNFL) segmentation and then divided into various number of super pixels. Unlike the conventional super pixel having a fixed number of points, this newly developed variable-size super pixel is defined as a cluster of homogeneous adjacent pixels with variable size, shape and number. Features of super pixel map were extracted and used as inputs to machine classifier (LogitBoost adaptive boosting) to automatically identify diseased eyes. For discriminating performance assessment, area under the curve (AUC) of the receiver operating characteristics of the machine classifier outputs were compared with the conventional circumpapillary RNFL (cpRNFL) thickness measurements. Results: The super pixel analysis showed statistically significantly higher AUC than the cpRNFL (0.855 vs. 0.707, respectively, p = 0.031, Jackknife test) when glaucoma suspects were discriminated from healthy, while no significant difference was found when confirmed glaucoma eyes were discriminated from healthy eyes. Conclusions: A novel 3D OCT analysis technique performed at least as well as the cpRNFL in glaucoma discrimination and even better at glaucoma suspect discrimination. This new method has the potential to improve early detection of glaucomatous damage. © 2013 Xu et al

    The effect of incorrect scanning distance on boundary detection errors and macular thickness measurements by spectral domain optical coherence tomography: a cross sectional study

    Get PDF
    BACKGROUND: To investigate the influence of scan distance on retinal boundary detection errors (RBDEs) and retinal thickness measurements by spectral domain optical coherence tomography (SD-OCT). METHODS: 10 eyes of healthy subjects, 10 eyes with diabetic macular edema (DME) and 10 eyes with neovascular age-related macular degeneration (AMD) were examined with RTVue SD-OCT. The MM5 protocol was used in two consecutive sessions to scan the macula. For the first session, the device was set 3.5 cm from the eye in order to obtain detectable signal with low fundus image quality (suboptimal setting) while in the second session a distance of 2.5 cm was set with a good quality fundus image. The signal strength (SSI) value was recorded. The score for retinal boundary detection errors (RBDE) was calculated for ten scans of each examination. RBDE scores were recorded for the whole scan and also for the peripheral 1.0 mm region. RBDE scores, regional retinal thickness values and SSI values between the two sessions were compared. The correlation between SSI and the number of RBDEs was also examined. RESULTS: The SSI was significantly lower with suboptimal settings compared to optimal settings (63.9+/-12.0 vs. 68.3+/-12.2, respectively, p = 0.001) and the number of RBDEs was significantly higher with suboptimal settings in the "all-eyes" group along with the group of healthy subjects and eyes with DME (9.1+/-6.5 vs. 6.8+/-6.3, p = 0.007; 4.4+/-2.6 vs. 2.5+/-1.6, p = 0.035 and 9.7+/-3.3 vs. 5.1+/-3.7, p = 0.008, respectively). For these groups, significant negative correlation was found between the SSI and the number of RBDEs. In the AMD group, the number of RBDEs was markedly higher compared to the other groups and there was no difference in RBDEs between optimal and suboptimal settings with the errors being independent of the SSI. There were significantly less peripheral RBDEs with optimal settings in the "all-eyes" group and the DME subgroup (2.7+/-2.6 vs. 4.2+/-2.8, p = 0.001 and 1.4+/-1.7 vs. 4.1+/-2.2, p = 0.007, respectively). Retinal thickness in the two settings was significantly different only in the outer-superior region in DME. CONCLUSIONS: Optimal distance settings improve SD-OCT SSI with a decrease in RBDEs while retinal thickness measurements are independent of scanning distance

    Optical coherence tomography: an assessment of current training across all levels of seniority in 8 ophthalmic units in the united kingdom

    Get PDF
    BACKGROUND: Optical Coherence Tomography (OCT) is becoming an increasingly integral part of ophthalmological clinical practice. The accurate interpretation of OCT images is important both in terms of diagnosis and in directing subsequent management. The aim of this study was to determine the clinical competence in OCT image interpretation of ophthalmologists in different subspecialties and grades. METHODS: Eight OCT images demonstrating a single macular pathology and two normal scans were selected by case notes review. These ten images were shown to thirty doctors and 10 non-medical staff from eight units. They were asked to identify each lesion, the average thickness of the lesion, and the axis at which the OCT was taken. One point was awarded for each correct answer. RESULTS: The mean scores for the correct qualitative identification of the OCT lesion (with a maximum score of 10) for different grades of doctors and non-medical staff were as follows: medical retinal consultants (MRC), 9 (range, 8–10); vitreoretinal consultants (VRC), 7 (range, 6–9); non-retinal consultants (NRC), 4 (range, 2–6); vitreoretinal fellows (VRF), 4 (range, 3–7); specialist registrars (SpR), 3 (range, 2–5); senior house officers (SHO), 4 (range, 3–6); orthoptists, 1 (range, 0–1); ancillary staff, 2 (range, 0–3). CONCLUSION: A wide range in the ability to accurately interpret OCT images has been demonstrated. All doctors would thereby benefit from further training in the interpretation of OCT scans

    Subsurface Defect Detection in Ceramic Materials Using Optical Gating Techniques

    Get PDF
    Components made from advanced ceramics materials, because of their thermomechanical and chemical properties, have several advantages over traditional steel parts, making them well suited for use in severe operating environments. In particular, silicon nitride (Si3N4) ceramics, because of their stiffness and resistance to corrosion, are being considered for use in rolling contact elements such as bearings and contact races. In addition, when combined with rare-earth oxide sintering aids such as yttria (Y2O3), silicon nitride ceramics have high-temperature strength which makes them excellent candidates for components such as rotors and blades in advanced turbine engines

    Age effect on retina and optic disc normal values

    Get PDF
    Purpose: To investigate retinal thickness and optic disc parameters by the Retinal Thickness Analyzer (RTA) glaucoma program in older normal subjects and to determine any age effect. Methods: Subjects over 40 years of age without any prior history of eye diseases were recruited. Only subjects completely normal on clinical ophthalmologic examination and on visual field testing by Humphrey Field Analyzer (HFA) using the SITA 24-2 program were included. A total of 74 eyes from 74 subjects with even age distribution over the decades were enrolled and underwent topographic measurements of the posterior pole and of the optic disc by RTA. The `glaucoma full' program in software version 4.11B was applied. Results: Mean patient age was 59.9 +/- 10.3 years with a range from 40 to 80 years. The only parameter intraocular pressure (IOP) correlated with was retinal posterior pole asymmetry (r=0.27, p=0.02). IOP itself increased significantly with age (r=0.341, p=0.003). Mean defect and pattern standard deviation of the HFA did not correlate with any of the retinal or optic disc measurements. Increasing age correlated significantly with some of the morphologic measurements of the RTA: decreasing perifoveal minimum thickness (r=-0.258, p=0.026), increased cup-to-disc area ratio (r=0.302, p=0.016) and increased cup area (r=0.338 p=0.007). Conclusions: An age effect exists for some of the retina and optic disc measurements obtained by the RTA. Copyright (C) 2005 S. Karger AG, Basel

    5-dim Superconformal Index with Enhanced En Global Symmetry

    Full text link
    The five-dimensional N=1\mathcal{N}=1 supersymmetric gauge theory with Sp(N) gauge group and SO(2N_f) flavor symmetry describes the physics on N D4-branes with NfN_f D8-branes on top of a single O8 orientifold plane in Type I' theory. This theory is known to be superconformal at the strong coupling limit with the enhanced global symmetry ENf+1E_{N_f+1} for Nf7N_f\le 7. In this work we calculate the superconformal index on S1×S4S^1\times S^4 for the Sp(1) gauge theory by the localization method and confirm such enhancement of the global symmetry at the superconformal limit for Nf5N_f\le 5 to a few leading orders in the chemical potential. Both perturbative and (anti)instanton contributions are present in this calculation. For Nf=6,7N_f=6,7 cases some issues related the pole structure of the instanton calculation could not be resolved and here we could provide only some suggestive answer for the leading contributions to the index. For the Sp(N) case, similar issues related to the pole structure appear.Comment: 70 pages, references added, published versio

    M5-branes from gauge theories on the 5-sphere

    Get PDF
    We use the 5-sphere partition functions of supersymmetric Yang-Mills theories to explore the (2,0) superconformal theory on S^5 x S^1. The 5d theories can be regarded as Scherk-Schwarz reductions of the 6d theory along the circle. In a special limit, the perturbative partition function takes the form of the Chern-Simons partition function on S^3. With a simple non-perturbative completion, it becomes a 6d index which captures the degeneracy of a sector of BPS states as well as the index version of the vacuum Casimir energy. The Casimir energy exhibits the N^3 scaling at large N. The large N index for U(N) gauge group also completely agrees with the supergravity index on AdS_7 x S^4.Comment: 44 pages, 1 figure, v4: ref added, clarified weak/strong coupling behaviors of large N free energy, minor improvements, version to be published in JHE

    Use of quercetin in animal feed : effects on the P-gp expression and pharmacokinetics of orally administrated enrofloxacin in chicken

    Get PDF
    Modulation of P-glycoprotein (P-gp, encoded by Mdr1) by xenobiotics plays central role in pharmacokinetics of various drugs. Quercetin has a potential to modulate P-gp in rodents, however, its effects on P-gp modulation in chicken are still unclear. Herein, study reports role of quercetin in modulation of P-gp expression and subsequent effects on the pharmacokinetics of enrofloxacin in broilers. Results show that P-gp expression was increased in a dose-dependent manner following exposure to quercetin in Caco-2 cells and tissues of chicken. Absorption rate constant and apparent permeability coefficient of rhodamine 123 were decreased, reflecting efflux function of P-gp in chicken intestine increased by quercetin. Quercetin altered pharmacokinetic of enrofloxacin by decreasing area under curve, peak concentration, and time to reach peak concentration and by increasing clearance rate. Molecular docking shows quercetin can form favorable interactions with binding pocket of chicken xenobiotic receptor (CXR). Results provide convincing evidence that quercetin induced P-gp expression in tissues by possible interaction with CXR, and consequently reducing bioavailability of orally administered enrofloxacin through restricting its intestinal absorption and liver/kidney clearance in broilers. The results can be further extended to guide reasonable use of quercetin to avoid drug-feed interaction occurred with co-administered enrofloxacin or other similar antimicrobials.Peer reviewedFinal Published versio

    On instantons as Kaluza-Klein modes of M5-branes

    Full text link
    Instantons and W-bosons in 5d maximally supersymmetric Yang-Mills theory arise from a circle compactification of the 6d (2,0) theory as Kaluza-Klein modes and winding self-dual strings, respectively. We study an index which counts BPS instantons with electric charges in Coulomb and symmetric phases. We first prove the existence of unique threshold bound state of (noncommutative) U(1) instantons for any instanton number, and also show that charged instantons in the Coulomb phase correctly give the degeneracy of SU(2) self-dual strings. By studying SU(N) self-dual strings in the Coulomb phase, we find novel momentum-carrying degrees on the worldsheet. The total number of these degrees equals the anomaly coefficient of SU(N) (2,0) theory. We finally show that our index can be used to study the symmetric phase of this theory, and provide an interpretation as the superconformal index of the sigma model on instanton moduli space.Comment: 54 pages, 2 figures. v2: references added, figure improved, added comments on self-dual string anomaly, added new materials on the symmetric phase index, other minor correction
    corecore